Avanta Plus Heat Only Boilers 12v | 15v | 18v | 24v | 30v

Technical Specifications

Heat Only Range

12v

15v

18v

24v

30v

Part Number (boiler only)

90449

90511

90279

90450

90512

Gas Council Number

41-288-09

41-288-13

41-288-06

41-288-10

41-28814

Gas

 

 

 

 

 

Gas Supply Pipe Size, mm

22

22

22

22

22

Natural Gas

Yes

Yes

Yes

Yes

Yes

LPG (Butane / Propane)

Yes

Yes

Yes

Yes

Yes

Nominal Inlet Supply Pressure NG / LPG, mbar

20 – 25

20 – 25

20 – 25

20 – 25

20 – 25

Gas Consumption Natural Gas, mg³/hr

1.3

1.6

1.8

2.7

3.2

Gas Flue Rate, kg/hr

20.5

25.8

31.0

42.4

50.5

Gas Inlet Pressure LPG, mbar

37 – 50

37 – 50

37 – 50

37 – 50

37 – 50

Gas Consumption LPG, mg³/hr

0.5

0.6

0.7

1.0

1.2

Classification due to discharging flue gases

B23, B33, C13, C33, C43, C53,  C63, C83

Gas Inlet Pressure Natural Gas, mbar

20 – 25

20 – 25

20 – 25

20 – 25

20 – 25

Nominal Output Ph (80/60ºC), kW

12.1

15.0

17.6

23.5

29.4

Nominal Output Ph (50/30ºC), kW

12.8

15.8

19.0

25.0

31.3

Nominal Input Qh, kW

5.8 – 12.3

5.8 – 15.3

5.8 – 18.0

6.1 – 25.2

6.1 – 30.0

Nominal Input Qhw, kW

12.3

15.3

18.0

25.2

30.0

Noise Level at a distance of 1m from the boiler (at full load), Db(A)

<44

<44

<44

<44

<44

Seasonal Efficiency NG / LPG (2005), %

90.1

90.4

90.5

90.3

90.4

SEDBUK Rating, Band

A

A

A

A

A

Seasonal Efficiency NG / LPG (2009), %

88.8

88.9

89.2

88.8

99.9

NOx Class

5

5

5

5

5

NOx Levels, ppm

<30

<30

<30

<30

<30

NOx Levels, mg/kWhr

< 53

< 53

< 53

< 53

< 53

Electrical

 

 

 

 

 

Electrical Supply, Volts / Hz

230 / 50

230 / 50

230 / 50

230 / 50

230 / 50

Permanent Live Required

Yes

Yes

Yes

Yes

Yes

Fitted Electrical Cable

Yes

Yes

Yes

Yes

Yes

Power Consumption, Watts

50

50

50

115

115

Power Consumption In Stand By Mode, Watts

<3

<3

<3

<3

<3

External Fuse Rating, Amps

3

3

3

3

3

Ingress Protection Rating (without mechanical timer fitted), IP

X4D

X4D

X4D

X4D

X4D

24 Hour Pump Overrun

Yes

Yes

Yes

Yes

Yes

Integral Boiler Only Frost Thermostat

No

No

No

No

No

Heat Only Range

12v

15v

18v

24v

30v

Controls

 

 

 

 

 

Concealed User Controls

No

No

No

No

No

On/Off Switch with Reset

Yes

Yes

Yes

Yes

Yes

User Adjustable DHW Temperature

-

-

-

-

-

User Adjustable CH Temperature

Yes

Yes

Yes

Yes

Yes

Mechanical & Hydraulic

 

 

 

 

 

Compartment Ventilation Requirement

No

No

No

No

No

Pre Plumbing / Wall Mounting Jig

Yes

Yes

Yes

Yes

Yes

CH Flow & Return Pipe Size, mm

22

22

22

22

22

Condensate Discharge Pipe Size, Inch

3/4

3/4

3/4

3/4

3/4

Integral Automatic Bypass

No

No

No

No

No

CH Water Capacity (heat exchanger and piping), litres

1.8

1.8

1.8

2.0

2.0

Minimum Operating Water Pressure, bar

0.1

0.1

0.1

0.1

0.1

Maximum CH Operating Water Pressure PMS, bar

3

3

3

3

3

CH Water Temperature
(Maximum), ºC

98

98

98

98

98

CH Operating Temperature, ºC

75

75

75

75

75

Safety Discharge Pressure, bar

3

3

3

3

3

Water Pressure Loss ∆T = 11′, bar

220

330

450

630

970

Filling Loop Included

No

No

No

No

No

CH System Inhibitor Required

Yes

Yes

Yes

Yes

Yes

Concentric Flue System

 

 

 

 

 

Standard Telescopic Horizontal Flue Kit Length, mm

250-450

250-450

250-450

250-450

250-450

Max Equiv Length Horizontal/Vertical 60/100, m

8

8

8

8

8

Max Equiv Length Horizontal/Vertical 80/125, m

34

34

34

34

34

Equivalent Length per 135º Bend, m

1.4

1.4

1.4

1.4

1.4

Equivalent Length per 93º Bend, m

0.65

0.65

0.65

0.65

0.65

Weights

 

 

 

 

 

Max Installation Lift Weight, kg

20

20

20

21.5

21.5

Gross Packaged Boiler Weight, kg

24

24

24

26

26


▲scroll to the top